Matters needing attention during the installation and use of the reducer


  1. Hammering is strictly prohibited


  When installing couplings, belt pulleys, sprocket and other connecting parts on the output shaft of the reducer, direct hammering is not allowed. Because the output shaft structure of the reducer cannot withstand axial hammering, it can be screwed in by the screw hole at the shaft end. The screw is pressed into the coupling piece.


  2. Be sure to install a breather cap (exhaust screw plug)


  Before use, replace the plug at the highest position with an exhaust plug to ensure that the gas in the body is exhausted when the reducer is running.If it is not replaced in time, the reducer will run for a long time, causing the gas in the reducer to swell the oil seal, and even the reducer will leak oil.


  3. Replace the lubricating oil in time, pay special attention to the first time.


  Special attention should be paid to the first oil change. The reducer should be replaced in time after 300 to 400 hours of operation for the first time, and then every 1500 to 2000 hours.In addition, the lubricating oil should be checked every half a month in the work environment with harsh working environment, high temperature and heavy dust. If the lubricating oil is found to be dirty, replace the lubricating oil to keep the lubricating oil clean and extend the use of the reducer. Longevity, improve economic efficiency.